Air circuit breaker WEW1-6300 air Circuit Breaker withdrawable type acb fixed type type Switch 400VAC/690VAC 6300A 3/4p acb
The Future of 400V Air Circuit Breakers
As the demands on electrical systems continue to evolve, the role of 400V air circuit breakers is poised to expand further. With advancements in digitalization, automation, and energy management, the integration of intelligent features and predictive maintenance capabilities in 400V air circuit breakers is becoming increasingly prevalent. These developments are aimed at enhancing the reliability, efficiency, and safety of electrical installations, aligning with the broader industry trends towards smart and sustainable infrastructure.
Moreover, the ongoing emphasis on energy efficiency and environmental sustainability is driving the adoption of innovative technologies in circuit protection, including 400V air circuit breakers. The integration of energy monitoring and power quality analysis functions in these circuit breakers enables better insight into electrical consumption patterns and facilitates the implementation of energy-saving measures, contributing to overall resource optimization and reduced environmental impact.
In conclusion, 400V air circuit breakers play a pivotal role in ensuring the safety, reliability, and efficiency of electrical systems across a diverse spectrum of applications. With their robust design, advanced protection features, and adaptability to evolving technological trends, these circuit breakers continue to be indispensable components in modern electrical installations. As the industry continues to embrace digitalization and sustainability, the evolution of 400V air circuit breakers is set to align with the changing landscape of electrical engineering, further enhancing the capabilities and performance of these critical devices.
Main performance index of WEW1 series circuit breaker
|
WEW1 Moulded Case Circuit Breaker |
6300 | ||||||||||||
Rated operating current In (A),40℃ |
4000-5000-6300 | ||||||||||||
| Rated insulation voltage Ui (V) | 1000 | ||||||||||||
| Rated impulse withstand voltage (kV) | 12 | ||||||||||||
| Rated operational voltage Ue(V),AC 50/60Hz | 400V/690V | ||||||||||||
| Use category | B | ||||||||||||
| Rated operational voltage Ue(V),AC 50/60Hz | 100%In | ||||||||||||
| Breaking capacity code | M | H | |||||||||||
Number of poles |
3P | ■ | ■ | ||||||||||
| 4P | ■ | ■ | |||||||||||
|
Rated ultimate
short-circuit breaking
capacity Icu (kA)
|
AC380V/400V/415V | 120 | 138 | ||||||||||
| AC690V | 85 | 105 | |||||||||||
|
Rated service breaking
capacity Ics (kA)
|
AC220/230/240V | 100 | 138 | ||||||||||
| AC380/400/415V | 85 | 105 | |||||||||||
Rated short-time withstand
current Icw (kA/1s)
|
AC220/230/240V | 100 | 138 | ||||||||||
| AC380/400/415V | 85 | 105 | |||||||||||
|
Mechanical life
(CO recycle)
|
Maintenance | 16000 | |||||||||||
Electrical life
(CO recycle)
|
AC415V,In | 6000 | |||||||||||
| AC690V,In | 2000 | ||||||||||||
| Standard configuration | Fixed | Drawetry-pe | |||||||||||
| The body of the circuit breaker | ■ | ■ | |||||||||||
| Drawer base | ■ | ■ | |||||||||||
| Intelligent controller | ■ | ■ | |||||||||||
| Upper and lower horizontal connecting wires | ■ | ■ | |||||||||||
| Indicating contact of opening/closing | ■ | ■ | |||||||||||
| Indicating contact of fault tripping | ■ | ■ | |||||||||||
| Auxiliary contact 4NO+4NC | ■ | ■ | |||||||||||
| Electric motor operating mechanism | ■ | ■ | |||||||||||
| Shunt releas | ■ | ■ | |||||||||||
| Optional accessories | |||||||||||||
| Phase partition | Fixed | Drawetry-pe | |||||||||||
| Instantaneous undervoltage release | □ | □ | |||||||||||
| Time-delay undervoltage release | □ | □ | |||||||||||
| Opening and closing button lock | □ | □ | |||||||||||
| Lock for the drawer base | □ | □ | |||||||||||
| Lock for the separation position of the drawer seat | □ | □ | |||||||||||
| Key lock | □ | □ | |||||||||||
| Door interlock | □ | □ | |||||||||||
| Auxiliary contact 6NO+6NC | □ | □ | |||||||||||
| Electric indications of three positions on the drawer base | □ | □ | |||||||||||
| Steel cable interlock | □ | □ | |||||||||||
| Locking interlock | □ | □ | |||||||||||
| Dual power controller | □ | □ | |||||||||||
| External neutral line transformer | □ | □ | |||||||||||
| Zero-sequence transformer | □ | □ | |||||||||||
| Ground current transformer and its accessories | □ | □ | |||||||||||
| Dimension | |||||||||||||
Dimension (mm)
W×H×D
|
Width (3P/4P) | 105/105 | 105/105 | ||||||||||
| Height | 62/62 | 62/62 | |||||||||||
| Depth | 61/61 | 61/61 | |||||||||||
| Weight | |||||||||||||
Weight(kg)/Fixed |
1P | 110/120/130 | |||||||||||
| 2P | 140.3/151.2/162.3 | ||||||||||||
| Weight(kg)/Drawer | 3P | 175/200/220 | |||||||||||
| 4P | 175/200/220 | ||||||||||||
Main performance index of WEW1 series circuit breaker

010203040506

JCB1-125
JCB2-40M
JCB3-63DC
JCB3-80H
JCB3-80M
JCBH-125
JC125-4P
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCR1-40
JCB2LE-80M
JCB2LE-80M
JCB2LE-80M
JCB2LE-40M
JCB1LE-125
JCB3LM-80
JCH2-125
JCH2-125
CJX2
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM6ELY-1250A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
JCB3-63DC
JCB1-125DC
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500