Analysis of environmental factors when using universal circuit breaker
The environment in which the universal circuit breaker is used is crucial to its performance and service life. In addition to the temperature, humidity and contamination levels already mentioned, there are many other environmental factors that need to be considered and are critical to ensuring reliable and safe operation of universal circuit breakers. First, the ambient air temperature should not exceed +40°C or be lower than -5°C, and the average value within 24 hours should not exceed +35°C. This temperature range is critical to ensure proper circuit breaker operation and prevent components from overheating or freezing. In addition, the altitude of the installation site should not exceed 2000m. Too high an altitude will affect the performance of the equipment. Relative humidity is another important factor to consider when using universal circuit breakers. When the ambient air temperature is +40°C, the relative humidity of the atmosphere should not exceed 50%. Higher relative humidity is allowed at lower temperatures, and possible condensation on the product surface due to temperature changes must also be considered. The average maximum relative humidity in the wettest month does not exceed 90%, and the average monthly minimum temperature is +25°C.

In some industrial environments, the use environment of universal circuit breakers should also consider vibration and shock. The equipment may be subject to vibration and shock, which may affect the performance and stability of the circuit breaker. Therefore, in these environments, it is necessary to select a circuit breaker that can withstand vibration and shock, or to take additional protective measures to protect the circuit breaker.
In some industrial environments, electromagnetic interference is also an important consideration, and there may be a large amount of electromagnetic interference that may affect the normal operation of the circuit breaker. Therefore, in these environments, it is necessary to choose a circuit breaker with good anti-interference ability to ensure that it can work stably and reliably.
In some special environments, the use environment of universal circuit breakers should also consider the influence of air quality and chemical substances. Harmful gases or chemicals may be present, which may affect the material and electrical performance of the circuit breaker. Therefore, in these environments, circuit breakers that can withstand chemical corrosion and harmful gas erosion must be selected to ensure long-term stable operation.
In some critical applications, the use environment of universal circuit breakers should also consider reliability and safety requirements. The reliability and safety requirements of circuit breakers are very high. Therefore, it is necessary to select circuit breakers that comply with corresponding standards and certifications, and strictly follow Installation and maintenance are required to ensure that they meet specific reliability and safety requirements.
In short, understanding the environment in which the universal circuit breaker is used is crucial to ensuring its reliable and safe operation. By considering factors such as vibration, shock, electromagnetic interference, air quality, the impact of chemical substances, and reliability and safety requirements, users can select a universal circuit breaker suitable for a specific environment and take appropriate installation and maintenance measures to ensure its performance and service life.

JCB1-125
JCB2-40M
JCB3-63DC
JCB3-80H
JCB3-80M
JCBH-125
JC125-4P
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCR1-40
JCB2LE-80M
JCB2LE-80M
JCB2LE-80M
JCB2LE-40M
JCB1LE-125
JCB3LM-80
JCH2-125
JCH2-125
CJX2
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM6ELY-1250A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
JCB3-63DC
JCB1-125DC
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500