Auxiliary Contacts for MCCBs: Functions and Standards
Molded Case Circuit Breakers (MCCBs) are essential components in electrical distribution systems, providing protection against overcurrent conditions such as overloads and short circuits. Auxiliary contacts are crucial accessories for MCCBs, offering additional functionalities like signaling and control. This article delves into the specifics of auxiliary contact double auxiliary with wiring or terminal, highlighting their functions, standards, and applications, particularly in photovoltaic distribution lines.

Functions of Auxiliary Contact Double Auxiliary
Auxiliary contacts serve as secondary switching devices that complement the main contacts of an MCCB. The double auxiliary contact configuration provides enhanced functionality and flexibility in control and monitoring applications. Here are the primary functions:
- Signaling: Auxiliary contacts provide status signals (open or closed) of the MCCB to remote monitoring systems or control panels. This is vital for real-time monitoring and ensuring the safety and reliability of the electrical distribution system.
 - Control: They enable remote operation of the MCCB Accessories, allowing for automatic or manual opening and closing based on specific conditions. This is particularly useful in automated systems where quick response to electrical faults is necessary.
 - Safety Interlocks: Auxiliary contacts can be used to create interlock systems that prevent unintended operations, enhancing the safety of maintenance personnel and equipment.
 - Fault Indication: Auxiliary contacts can indicate specific types of faults, such as short circuits or overloads, helping maintenance personnel quickly identify and address issues. This can significantly reduce downtime and improve system reliability.
 - Load Shedding: In scenarios where load management is critical, auxiliary contacts can be used to shed non-essential loads during peak usage times or under fault conditions. This helps maintain the stability of the electrical system and prevents overloading.
 - Sequential Control: They can be used to implement sequential control of connected devices, ensuring that equipment powers on or off in a specific order. This is important in systems where certain components need to be activated or deactivated in a controlled sequence to avoid damage or operational issues.
 - Remote Monitoring and Diagnostics: By providing real-time data to monitoring systems, auxiliary contacts enable remote diagnostics of the electrical system. This facilitates preventive maintenance and allows for quicker response to potential problems.
 - Energy Management: Auxiliary contacts can be integrated into energy management systems to monitor and control energy usage more effectively. They provide valuable data that can be used to optimize energy consumption and reduce operational costs.
 - Automation Integration: In modern automated systems, auxiliary contacts can interface with programmable logic controllers (PLCs) and other automation equipment. This integration allows for advanced control strategies and enhances the overall efficiency of the electrical distribution system.
 - Emergency Shutdown: Auxiliary contacts can be part of an emergency shutdown system, ensuring that power is quickly and safely disconnected in critical situations. This function is essential for protecting both personnel and equipment from potential hazards.
 

Applications in Photovoltaic Distribution Lines
In photovoltaic (PV) distribution systems, the stability and reliability of power supply are paramount. The auxiliary contact double auxiliary with wiring or terminal plays a critical role in managing overvoltage and undervoltage conditions. Here's how:
Automatic Opening and Closing:
- Overvoltage or Undervoltage: When the system detects overvoltage or undervoltage, the auxiliary contacts delay the opening of the circuit to protect the equipment. This prevents immediate disconnection that could lead to system instability.
 - Voltage Normalization: Once the voltage returns to normal levels, the auxiliary contacts automatically close the circuit, restoring power supply without manual intervention.
 - Voltage Loss or Breakage: In case of voltage loss or a broken supply line, the contacts delay opening to allow for temporary voltage fluctuations, ensuring that the circuit only opens if the condition persists.
 
Manual Mode:
- Overvoltage or Undervoltage: In manual mode, the auxiliary contacts still respond to overvoltage or undervoltage by opening the circuit but require manual intervention to close the circuit once normal voltage is restored. This provides additional control for operators who need to manage the system more closely.
 
Technical Specifications
The auxiliary contact double auxiliary with wiring or terminal used in MCCBs for PV distribution lines must meet specific technical standards to ensure safety and performance. Here are the technical specifications:
- Rated Insulation Voltage: 500V
 - Frequency: Suitable for 50Hz or 60Hz systems
 - Rated Working Voltage: 230V/400V
 - Rated Current: Up to 125A distribution lines
 - Operating Temperature Range: -20?C to +70?C, ensuring reliable performance in various environmental conditions.
 - Mechanical Endurance: Minimum of 10,000 operations, indicating the durability and long lifespan of the auxiliary contacts.
 - Electrical Endurance: Minimum of 2,000 operations at rated current, ensuring consistent performance under electrical load conditions.
 - Mounting Compatibility: Designed to fit standard DIN rail mounting systems, facilitating easy integration into existing electrical panels.
 - Contact Configuration: Available in various contact configurations such as NO (Normally Open), NC (Normally Closed), or a combination of both, providing flexibility in control circuit design.
 - Contact Rating: Typically rated for 6A at 230V AC or 2A at 24V DC, ensuring compatibility with various signaling and control circuits.
 
These specifications ensure that the auxiliary contacts can handle the electrical demands of PV distribution systems, providing reliable operation under various conditions.
Compliance with Standards
To ensure quality and reliability, the auxiliary contact double auxiliary must comply with relevant standards. These include:
- GB/T 10963.1: This standard pertains to electrical accessories, specifically circuit breakers for overcurrent protection in household and similar places. It outlines the requirements for AC use circuit breakers, ensuring they can safely operate under prescribed conditions.
 - GB/T 19334: This standard covers the dimensions of low-voltage switchgear and control equipment, including standard installation rails for electrical mechanical supports. Compliance ensures that the auxiliary contacts fit correctly in standardized equipment setups.
 - GB/T 21706: This standard relates to modular terminal combination electrical appliances, ensuring that auxiliary contacts are compatible with various modular setups, enhancing their versatility and ease of installation.
 
Auxiliary contact double auxiliary with wiring or terminal is an indispensable accessory for MCCBs, particularly in photovoltaic distribution lines. Their ability to manage overvoltage and undervoltage conditions automatically or manually, coupled with compliance with stringent standards, makes them vital for maintaining the stability and reliability of electrical distribution systems. By understanding their functions, applications, and technical specifications, operators can ensure optimal performance and safety in their electrical systems.

JCB1-125
JCB2-40M
JCB3-63DC
JCB3-80H
JCB3-80M
JCBH-125
JC125-4P
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCR1-40
JCB2LE-80M
JCB2LE-80M
JCB2LE-80M
JCB2LE-40M
JCB1LE-125
JCB3LM-80
JCH2-125
JCH2-125
CJX2
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM6ELY-1250A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
JCB3-63DC
JCB1-125DC
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300  2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500